高级检索
当前位置: 首页 > 详情页

Accuracy and Safety of Robot-Assisted versus Fluoroscopy-Guided Posterior C1 Lateral Mass and C2 Pedicle Screw Internal Fixation for Atlantoaxial Dislocation: A Preliminary Study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of orthopedics, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou 510120, China. [2]Postdoctoral Workstation, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou 510120, China. [3]Research Team on the Prevention and Treatment of Spinal Degenerative Disease, Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou 510006, China. [4]Postdoctoral Research Station, Chinese Academy of Chinese Medical Sciences, Beijing 100700, China. [5]Second Clinical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, China.
出处:
ISSN:

摘要:
To compare the accuracy, efficiency, and safety of robotic assistance (RA) and conventional fluoroscopy guidance for the placement of C1 lateral mass and C2 pedicle screws in posterior atlantoaxial fusion.The data of patients who underwent posterior C1-C2 screw fixation (Goel-Harm's technique) in our hospital from August 2014 to March 2021 were retrospectively evaluated, including 14 cases under fluoroscopic guidance and 11 cases under RA. The hospital records, radiographic results, surgical data, and follow-up records were reviewed. Accuracy of screw placement was assessed using the Gertzbein and Robbins scale, and clinical outcomes were evaluated by Japanese Orthopedic Association (JOA) score, visual analogue scale (VAS), modified MacNab criteria, and postoperative complications.Baseline characteristics of both groups were similar. The mean estimated blood loss in the fluoroscopic guidance and RA groups was 205.7 ± 80.3 mL and 120.9 ± 31.9 mL, respectively (p = 0.03). The mean surgical duration was 34 min longer with RA compared to that performed with free-hand (FH) method (p = 0.15). In addition, lower intraoperative radiation exposure was detected in the RA group (12.4 ± 1.4 mGy/screw) versus the FH (19.9 ± 2.1 mGy/screw) group (p = 0.01). The proportion of "clinically acceptable" screws (graded 0 and I) was higher in the RA group (93.2%) than that in the FH group (87.5%, p = 0.04). There was no significant difference in the increase of JOA score and decrease of VAS score between the two surgical procedures. Furthermore, there were no significant differences in overall clinical outcome between the two groups and no neurovascular complications associated with screw insertion.RA is a safe and potentially more accurate alternative to the conventional fluoroscopic-guided FH technique for posterior atlantoaxial internal fixation.Copyright © 2022 Jiheng Zhan et al.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 生物学
小类 | 3 区 生物工程与应用微生物 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 生物工程与应用微生物 4 区 医学:研究与实验
JCR分区:
出版当年[2020]版:
Q2 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Q3 MEDICINE, RESEARCH & EXPERIMENTAL
最新[2023]版:
Q3 BIOTECHNOLOGY & APPLIED MICROBIOLOGY Q3 MEDICINE, RESEARCH & EXPERIMENTAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Department of orthopedics, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou 510120, China. [2]Postdoctoral Workstation, Guangdong Provincial Hospital of Traditional Chinese Medicine, Guangzhou 510120, China. [3]Research Team on the Prevention and Treatment of Spinal Degenerative Disease, Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou 510006, China. [4]Postdoctoral Research Station, Chinese Academy of Chinese Medical Sciences, Beijing 100700, China.
共同第一作者:
通讯作者:
通讯机构: [1]Department of orthopedics, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou 510120, China. [3]Research Team on the Prevention and Treatment of Spinal Degenerative Disease, Guangdong Provincial Academy of Chinese Medical Sciences, Guangzhou 510006, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号