高级检索
当前位置: 首页 > 详情页

Interpretable CT radiomics model for invasiveness prediction in patients with ground-glass nodules

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, Jiaxing TCM Hospital Affiliated to Zhejiang Chinese Medical University, Jiaxing, China. [2]Department of Radiology, Shunde Hospital, Southern Medical University (The First People's Hospital of Shunde), Foshan, China. [3]The First School of Clinical Medicine, Zhejiang Chinese Medical University, Hangzhou, China. [4]Department of Radiology, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, China. [5]The First School of Clinical Medicine, Zhejiang Chinese Medical University, Hangzhou, China. Electronic address: xums166@zcmu.edu.cn. [6]Department of Radiology, Jiaxing TCM Hospital Affiliated to Zhejiang Chinese Medical University, Jiaxing, China. Electronic address: 13758064970@163.com. [7]Department of Radiology, Jiaxing TCM Hospital Affiliated to Zhejiang Chinese Medical University, Jiaxing, China. Electronic address: liangshan-li@163.com.
出处:
ISSN:

摘要:
To evaluate the performance of an interpretable computed tomography (CT) radiomic model in predicting the invasiveness of ground-glass nodules (GGNs).The study was conducted retrospectively from 1 August 2017 to 1 August 2022, at three different centres. Two hundred and thirty patients with GGNs were enrolled at centre I as a training cohort. Centres II (n=157) and III (n=156) formed two external validation cohorts. Radiomics features extracted based on CT were reduced by a coarse-fine feature screening strategy. A radiomic model was developed through the use of the LASSO (least absolute shrinkage and selection operator) and XGBoost algorithms. Then, a radiological model was established through multivariate logistic regression analysis. Finally, the interpretability of the model was explored using SHapley Additive exPlanations (SHAP).The radiomic XGBoost model outperformed the radiomic logistic model and radiological model in assessing the invasiveness of GGNs. The area under the curve (AUC) values for the radiomic XGBoost model were 0.885 (95% confidence interval [CI] 0.836-0.923), 0.853 (95% CI 0.790-0.906), and 0.838 (95% CI 0.773-0.902) in the training and the two external validation cohorts, respectively. The SHAP method allowed for both a quantitative and visual representation of how decisions were made using a given model for each individual patient. This can provide a deeper understanding of the decision-making mechanisms within the model and the factors that contribute to its prediction effectiveness.The present interpretable CT radiomics model has the potential to preoperatively evaluate the invasiveness of GGNs. Furthermore, it can provide personalised, image-based clinical-decision support.Copyright © 2023. Published by Elsevier Ltd.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 核医学
JCR分区:
出版当年[2022]版:
Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2022版] 出版当年五年平均 出版前一年[2021版] 出版后一年[2023版]

第一作者:
第一作者机构: [1]Department of Radiology, Jiaxing TCM Hospital Affiliated to Zhejiang Chinese Medical University, Jiaxing, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号