机构:[1]Rehabilitation Medical College, Shandong University of Traditional Chinese Medicine, Shandong, Jinan 250355, China[2]Department of Rehabilitation Medicine, Shenzhen Second People's Hospital, Guangdong, Shenzhen 518035, China深圳市第二人民医院深圳市康宁医院深圳医学信息中心[3]College of Computer Science and Control Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 5 18055, China[4]Huashan Hospital, Fudan University, Shanghai 200040, China[5]Shenzhen Flexolink Technology Co., Ltd, Shenzhen 518000, China ” School of Biomedical Engineering, Capital Medical University, Beijing 100069, China
Polysomnography (PSG) is the gold standard for clinical sleep monitoring, but its cost, discomfort, and limited suitability for continuous use present challenges. The flexible electrode sleep patch (FESP) emerges as an economically viable and patient-friendly solution, offering lightweight, simple operation, and self-applicable. Nevertheless, its utilization in young individuals remains uncertain.Compare sleep data obtained by FESP and PSG in healthy young individuals, analyzing agreement for sleep parameters and structure classification.Overnight monitoring with FESP and PSG recordings in 48 participants (mean age: 23 years). Correlation analysis, Bland-Altman plots, and Cohen's kappa coefficient assessed consistency. Sensitivity, specificity, and predictive values compared classification against PSG.FESP showed strong correlation and consistency with PSG for sleep monitoring. Bland-Altman plots indicated small errors and high consistency. Kappa values (0.70 to 0.84) suggested substantial agreement for sleep stage classification. Pearson correlation coefficient values for sleep stages (0.75 to 0.88) and sleep parameters (0.80 to 0.96) confirm that FESP has a strong application. Intraclass correlation coefficient yielded values between 0.65 to 0.97. Additionally, FESP demonstrated an impressive accuracy range of 84.12% to 93.47% for sleep stage classification. The FESP also features a wearable self-test program with an error rate of no more than 8% for both Deep sleep and Wake.In young adults, FESP demonstrated reliable monitoring capabilities comparable to PSG. With its low cost and user-friendly design, FESP is a potential alternative for portable sleep assessment in clinical and research applications. Further studies involving larger populations are needed to validate its diagnostic potential.
基金:
Shenzhen's Sanming Project "Nanjing Medical University Li Jian'an Team' Supporting
Project, Project Number: SZSM20211010; Shenzhen Natural Science Foundation, Project
Number: CYJ20230807115123047; Clinical Research Project of Shenzhen Second People's
Hospital, Project Number:20203357021, 2023yjleyj017
语种:
外文
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类|3 区医学
小类|3 区神经科学3 区生理学
最新[2025]版:
大类|4 区医学
小类|3 区生理学4 区神经科学
第一作者:
第一作者机构:[1]Rehabilitation Medical College, Shandong University of Traditional Chinese Medicine, Shandong, Jinan 250355, China
共同第一作者:
通讯作者:
通讯机构:[2]Department of Rehabilitation Medicine, Shenzhen Second People's Hospital, Guangdong, Shenzhen 518035, China[5]Shenzhen Flexolink Technology Co., Ltd, Shenzhen 518000, China ” School of Biomedical Engineering, Capital Medical University, Beijing 100069, China[*1]Shenzhen Flexolink Technology Co., Ltd, Shenzhen, China[*2]Department of Rehabilitation Medicine, Shenzhen Second People's Hospital, The First Affiliated Hospital of Shenzhen University, NO.3002 Sungang West Rd, Futian District,Guangdong, Shenzhen 518035, China
推荐引用方式(GB/T 7714):
Wang Yuqi,Zhou Jing,Zha Fubing,et al.Comparative Analysis of Sleep Parameters and Structures Derived from Wearable Flexible Electrode Sleep Patches and Polysomnography in Young Adults[J].Journal Of Neurophysiology.2024,doi:10.1152/jn.00465.2023.
APA:
Wang Yuqi,Zhou Jing,Zha Fubing,Zhou Mingchao,Li Dongxia...&Wang Yulong.(2024).Comparative Analysis of Sleep Parameters and Structures Derived from Wearable Flexible Electrode Sleep Patches and Polysomnography in Young Adults.Journal Of Neurophysiology,,
MLA:
Wang Yuqi,et al."Comparative Analysis of Sleep Parameters and Structures Derived from Wearable Flexible Electrode Sleep Patches and Polysomnography in Young Adults".Journal Of Neurophysiology .(2024)