高级检索
当前位置: 首页 > 详情页

The LISA-PPV Formula: An Ensemble Artificial Intelligence-Based Thick Intraocular Lens Calculation Formula for Vitrectomized Eyes

文献详情

资源类型:
Pubmed体系:
机构: [1]State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yatsen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China [2]Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China [3]Shenzhen Key Laboratory of Ophthalmology, Shenzhen Eye Hospital, Affiliated Hospital of Jinan University, Shenzhen, China [4]Department Of Ophthalmology, The People's Hospital Of Guangxi Zhuang Autonomous Region and Institute Of Ophthalmic Diseases, Guangxi Academy Of Medical Sciences, Nanning, Guangxi, China [5]Department of Ophthalmology, The First Affiliated Hospital of Guangxi University of Chinese Medicine, Nanning, China [6]Cataract Department, Shanxi Eye Hospital, Taiyuan, Shanxi Province, People's Republic of China.
出处:
ISSN:

关键词: Cataract Intraocular lens calculation Pars plana vitrectomy Prediction error

摘要:
To investigate the relationship between effective lens position (ELP) and patient characteristics, and to further develop a new intraocular lens (IOL) calculation formula for cataract patients with previous pars plana vitrectomy (PPV).Cross-sectional study.A total of 2793 age-related cataract patients (group 1) and 915 post-PPV cataract patients (group 2) who underwent phacoemulsification with IOL implantation were included. The ELP of two groups was compared and the association between ELP and patient characteristics was further evaluated using standardized multivariate regression coefficients. An ensemble artificial intelligence-based ELP prediction model was developed using a training set of 810 vitrectomized eyes, and a thick-lens IOL formula (LISA-PPV) was constructed and compared with seven existing formulas on an external multi-center testing set of 105 eyes.Compared to eyes with age-related cataract, vitrectomized eyes showed a similar ELP distribution (P = 0.19), but different standardized coefficients of preoperative biometry for ELP. The standardized coefficients also varied with the type of vitreous tamponade, history of scleral buckling, and ciliary sulcus IOL implantation. The LISA-PPV formula showed the lowest mean and median absolute prediction error (MAE: 0.63 D; MedAE: 0.44 D), and the highest percentages of eyes within ± 0.5 D of prediction error (57.14%) in the testing dataset.The ELP prediction required optimization specifically for vitrectomized eyes based on their biometric and surgical characteristics. The LISA-PPV formula is a useful and accurate tool for determining IOL power in cataract patients with previous PPV (available at http://ppv-iolcalculator.com/).Copyright © 2024. Published by Elsevier Inc.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 眼科学
第一作者:
第一作者机构: [1]State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yatsen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China [2]Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
通讯作者:
通讯机构: [1]State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yatsen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangzhou, China [2]Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2020 今日访问量:0 总访问量:646 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号