高级检索
当前位置: 首页 > 详情页

A half-percutaneous technique for peritoneal dialysis catheter implantation using a modified trocar: a report of 84 cases

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Nephrology, Guangdong Provincial Hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, No. 111 Dade Road, Guangzhou 510120, China [2]Department of Nephrology, Jilin City Central Hospital, No. 4 Nanjing Street, Jilin 132000, China
出处:
ISSN:

关键词: Peritoneal dialysis PD catheter implantation Modified trocar Half-percutaneous technique Short-term outcomes

摘要:
PurposePeritoneal dialysis (PD) catheter implantation is necessary for patients with end-stage renal disease (ESRD) to maintain continuous ambulatory PD (CAPD). In this study, we aimed to introduce a half-percutaneous technique based on a modified trocar device for the placement of a PD catheter and to evaluate the safety and efficacy of this technique and its associated short-term postoperative outcomes.MethodsEighty-four ESRD patients who underwent PD catheter implantation with the half-percutaneous technique were recruited retrospectively between September 2016 and October 2017 from the Guangdong Provincial Hospital of Chinese Medicine. All catheter implantation procedures were performed by the same three nephrologists. The surgical protocol was described in detail, and the general intraoperative parameters and short-term complications were evaluated.ResultsAll ESRD patients underwent successful PD catheterization with our novel technique. Neither conversion from this method to traditional open surgery nor major intraoperative complications were observed. The mean operative time was 20.84.5min, and the incision length was 2.28 +/- 0.53cm. The operative cost was CN yen 1762.45 (US $261), and the length of hospital stay was 7.5 +/- 0.58days. One patient (1.19%) showed leakage, and one patient (1.19%) experienced bleeding 2 weeks after the surgery. Catheter dysfunction due to catheter tip migration occurred in nine patients (10.7%) 2 weeks after the procedure, and the placement of the catheter was corrected with conservative treatment. No visceral injuries or PD-related infections were observed up to 4 weeks after the catheters were implanted.Conclusions This half-percutaneous technique for PD catheter implantation appears to be a safe, effective and feasible procedure. This technique has the advantages of reduced surgical trauma, a shorter operative time and faster postsurgical recovery. In particular, this novel technique is easy for nephrologists to perform and therefore may help to promote and popularize PD treatment.

语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 4 区 医学
小类 | 4 区 泌尿学与肾脏学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 泌尿学与肾脏学
JCR分区:
出版当年[2017]版:
Q3 UROLOGY & NEPHROLOGY
最新[2023]版:
Q3 UROLOGY & NEPHROLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Department of Nephrology, Guangdong Provincial Hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, No. 111 Dade Road, Guangzhou 510120, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号