How to carry out monthly blood flow surveillance of fistula in large-scale hemodialysis units: A cross-sectional study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Division of Nephrology, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China [2]School of Nursing, Southern Medical University, Guangzhou, China [3]Department of Rehabilitation Medicine, Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, China [4]Division of Nephrology, Guangzhou Nansha Central Hospital, Guangzhou, China
出处:
ISSN:

关键词: arteriovenous fistula blood flow Hemodialysis surveillance

摘要:
Background: The important effect of regular blood flow surveillance on arteriovenous fistula maintenance is emphasized. The ultrasonic dilution technique for blood flow surveillance can be performed during hemodialysis, but there are some limitations. Blood flow is traditionally measured by duplex Doppler ultrasound during the nondialysis period. However, the surveillance workload for arteriovenous fistula has increased with the rapid increase in the hemodialysis population size. Efficient methods for blood flow surveillance during hemodialysis are needed. Methods: Eighty-four hemodialysis patients with a forearm radiocephalic arteriovenous fistula were enrolled in this cross-sectional study. Each received blood flow measurements using ultrasonic dilution technique and duplex Doppler ultrasound during hemodialysis. Duplex Doppler ultrasound measurements included the blood flow of the brachial artery and radial artery. The correlations between these variables were analyzed. Results: The correlation coefficients (r) between flow measured by ultrasonic dilution technique and brachial artery flow measured by duplex Doppler ultrasound, between flow measured by ultrasonic dilution technique and radial artery flow measured by duplex Doppler ultrasound, and between brachial artery flow and radial artery flow measured by duplex Doppler ultrasound were 0.724, 0.784, and 0.749, respectively (all p < 0.001). Conclusion: Blood flow measured by ultrasonic dilution technique was positively correlated with blood flow measured by duplex Doppler ultrasound during hemodialysis, suggesting that duplex Doppler ultrasound can be used to monitor the trends in the blood flow of the brachial artery and radial artery for timely intervention to improve patency during hemodialysis. © The Author(s) 2020.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 外周血管病
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 外周血管病
JCR分区:
出版当年[2019]版:
Q4 PERIPHERAL VASCULAR DISEASE
最新[2023]版:
Q3 PERIPHERAL VASCULAR DISEASE

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]Division of Nephrology, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China [2]School of Nursing, Southern Medical University, Guangzhou, China
共同第一作者:
通讯作者:
通讯机构: [1]Division of Nephrology, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou, China [2]School of Nursing, Southern Medical University, Guangzhou, China [*1]Division of Nephrology, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China. [*2]Division of Nephrology, Guangdong Provincial People’s Hospital, Guangdong Academy of Medical Sciences, Guangzhou 510080, China.
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号