高级检索
当前位置: 首页 > 详情页

Axial Spondyloarthritis: Dual-Energy Virtual Noncalcium CT in the Detection of Bone Marrow Edema in the Sacroiliac Joints.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Departments of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, 106 Zhongshan Er Rd, Guangzhou 510080, Guangdong, China [2]Departments of Rheumatism,Guangdong General Hospital, Guangdong Academy of Medical Sciences, 106 Zhongshan Er Rd, Guangzhou 510080, Guangdong, China [3]Departments of Orthopedics of Traditional Chinese Medicine, Guangdong General Hospital, Guangdong Academy of Medical Sciences, 106 Zhongshan Er Rd, Guangzhou 510080, Guangdong, China [4]Department of CT Collaboration, Siemens Healthcare, Guangzhou, China [5]Department of Information Media Industry, Guangzhou Public Utility Technician College, Guangzhou, China
出处:
ISSN:

摘要:
Purpose To determine the diagnostic performance of dual-energy virtual noncalcium (VNCa) CT in the detection of bone marrow edema in study participants with sacroiliitis associated with axial spondyloarthritis. Materials and Methods In this prospective study, 47 consecutive participants (mean age, 27 years; age range, 14-41 years [28 male; mean age, 24 years; age range, 14-37 years] [19 female; mean age, 29 years; age range, 17-41 years]) underwent dual-energy CT and 3.0-T MRI between April 2016 and December 2017. Two independent readers visually evaluated all sacroiliac joints for the presence of abnormal marrow attenuation on dual-energy VNCa images using a four-point classification system (0, no edema; 1, mild edema; 2, moderate edema; 3, severe edema). CT numbers on VNCa images were determined with region-of-interest-based quantitative analysis. MRI was the reference standard for presence of bone marrow edema. Results Sensitivity, specificity, and accuracy of readers 1 and 2, respectively, in the identification of bone edema at CT were 87% and 93% (48 and 51 of 55), 94% and 91% (32 and 31 of 34), and 90% and 92% (80 and 82 of 89). Interobserver agreement was excellent (κ = 0.81). CT numbers from VNCa images increased from no edema to severe edema (P < .001). The area under the receiver operating characteristic curve was 0.93 for reader 1 and 0.91 for reader 2 in differentiation of the presence of bone marrow edema from no edema. A cutoff value of -33 HU derived from reader 1 yielded overall sensitivity, specificity, and accuracy of 90% (49 of 55), 83% (28 of 34), and 87% (77 of 89) in the detection of any extent of edema in the sacroiliac joints. Conclusion Dual-energy VNCa CT images had excellent diagnostic performance in evaluation of the extent of bone marrow edema in study participants with sacroiliitis associated with axial spondyloarthritis. © RSNA, 2018 See also the editorial by Guggenberger in this issue.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 1 区 医学
小类 | 1 区 核医学
最新[2025]版:
大类 | 1 区 医学
小类 | 1 区 核医学
JCR分区:
出版当年[2017]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Departments of Radiology, Guangdong General Hospital, Guangdong Academy of Medical Sciences, 106 Zhongshan Er Rd, Guangzhou 510080, Guangdong, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号