Prosthesis design of animal models of periprosthetic joint infection following total knee arthroplasty: A systematic review.

文献详情

资源类型:
Pubmed体系:
机构: [1]The First Clinical Medical College, Guangzhou University of Chinese Medicine, Baiyun District, Guangzhou, Guangdong Province, China [2]The Third Department of Orthopedics, The First Affiliated Hospital of Guangzhou University of Chinese Medicine, Baiyun District, Guangzhou, Guangdong Province, China
出处:

摘要:
The number of periprosthetic joint infections (PJI) after total knee arthroplasty (TKA) is increasing annually. Animal models have been used to clarify their clinical characteristics and the infection mechanism of pathogenic bacteria, However, since the prosthesis design of animal models is not uniform, it is difficult to simulate the environment of clinical PJI. To retrospect the progress on the prosthesis design of animal models of PJI after TKA and to summarize the criteria for evaluating a clinically representative model of PJI. This systematic review was reported on the basis of Systematic Reviews and Meta-Analyzes (PRISMA). Pubmed, EMbase, Cochrane Library, Web of Science, Wanfang Data and China National Knowledge Infrastructure were researched for animal models of PJI after TKA from database establishment to April 2019 according to Chinese and English retrieval words, including "periprosthetic joint infections and total knee arthroplasty," "periprosthetic joint infections and model," "periprosthetic joint infections and biofilm," and "total knee arthroplasty and model." A total of 12 quantitative studies were enrolled in our study finally: 8 representative studies described prosthesis designs used in PJI animal models, 4 studies described prosthesis designs in non-infected animal models which were suitable for infection models. The major problems need to be dealed with were prosthesis, installation location, material, the function of separating the articular and medullary cavity, fixation manner, and the procedure of preserving the posterior cruciate ligament. A highly representative design of the animal prosthesis of PJI should meet the following criteria: the surface of the prosthesis is smooth with the formation of biofilm, composed of titanium-6Al-4V or cobalt-chromium-molybdenum alloy; prosthesis can bear weight and is highly stable; and it can connect the joint cavity and medullary cavity simultaneously. To reach a more reliable conclusion, further experiments and improvements are required.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 3 区 生物
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
第一作者:
第一作者机构: [1]The First Clinical Medical College, Guangzhou University of Chinese Medicine, Baiyun District, Guangzhou, Guangdong Province, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号