高级检索
当前位置: 首页 > 详情页

How to choose the suitable FNS specification in young patients with femoral neck fracture: A finite element analysis

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]The Second Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou 510006, China [2]The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou 510006, China
出处:
ISSN:

关键词: Femoral neck fracture Femoral neck system Cannulated screw Finite element analysis FEA

摘要:
Background: Consensus regarding the optimal approach for the treatment of femoral neck fractures remains lacking. A new internal fixation femoral neck system (FNS) was developed and used in clinical practice. We aimed to investigate the biomechanical outcomes of different types of FNS in the treatment of unstable femoral neck fractures. Method: In this study, we constructed three different types of unstable femoral neck fractures of Pauwels classification with angles of 50 degrees, 60 degrees, and 70 degrees. We set up four test groups, namely, the one-hole plated FNS group, two-hole plated FNS group, inverted cannulated screw group and triangle cannulated screw group. Under 2100 N axial loads, displacements and the von Mises stress of the femur and internal fixation components were measured for each fracture group. Results: When the Pauwels angle was 50 degrees or 60 degrees, the one-hole locking plated FNS was as superior as the two-hole plated FNS in terms of femur and internal fixation displacement, and the inverted cannulated screw had slightly better stability than the triangular cannulated screw. However, when the angle increases to 70 degrees, the two-hole locking plate has the minimum displacement, followed by the triangular cannulated screw and inverted cannulated screw, which is the worst displacement for the single-hole locking plate. Regardless of the angle, the two sets of FNS have higher internal fixation stress than the two sets of cannulated screws, which is approximately 1.6-3.0 times that of the cannulated screw group. Conclusion: From the perspective of biomechanics, we suggest that when the angle of the fracture line is less than 60 degrees, both single-hole locking plated or double-hole locking plated FNS can be used to treat unstable femoral neck fractures. However, when the angle of the fracture line is greater than 70 degrees, we recommend using a double-hole locking plated FNS. This result needs further verification in further clinical studies. (C) 2021 Elsevier Ltd. All rights reserved.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 3 区 急救医学 3 区 骨科 3 区 外科 4 区 危重病医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 急救医学 3 区 骨科 3 区 外科 4 区 危重病医学
JCR分区:
出版当年[2019]版:
Q2 EMERGENCY MEDICINE Q2 SURGERY Q2 ORTHOPEDICS Q3 CRITICAL CARE MEDICINE
最新[2023]版:
Q2 EMERGENCY MEDICINE Q2 ORTHOPEDICS Q2 SURGERY Q3 CRITICAL CARE MEDICINE

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [1]The Second Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou 510006, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2020 今日访问量:0 总访问量:646 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号