Changes in hip joint contact stress during a gait cycle based on the individualized modeling method of "gait-musculoskeletal system-finite element".

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, Guangdong, China. [2]The Lab of Orthopaedics of ChineseMedicine of Lingnan Medical Research Center, Guangzhou University of Chinese Medicine, Guangzhou 510405, Guangdong, China. [3]Department of Joint Orthopaedic, the First Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou 510405, Guangdong, China. [4]Guangzhou University, Guangzhou 510006, Guangdong, China [5]Brain Hospital Affiliated to Jinan University, Guangzhou 510510, Guangdong, China. [6]The Third Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou 510240, Guangdong, China. [7]Present Address: Second People’s Hospital of Shenzhen, Shenzhen 518000, Guangdong, China.
出处:
ISSN:

摘要:
To construct a comprehensive simulation method of "gait-musculoskeletal system (MS)-finite element (FE)" for analysis of hip joint dynamics characteristics and the changes in the contact stress in the hip throughout a gait cycle.Two healthy volunteers (male and female) were recruited. The 3D gait trajectories during normal walking and the CT images including the hip and femur of the volunteers were obtained. CT imaging data in the DICOM format were extracted for subjected 3D hip joint reconstruction. The reconstructed 3D model files were used to realize the subject-specific registration of the pelvis and thigh segment of general musculoskeletal model. The captured marker trajectory data were used to drive subject-specific musculoskeletal model to complete inverse dynamic analysis. Results of inverse dynamic analysis were exported and applied as boundary and load settings of the hip joint finite element in ABAQUS. Finally, the finite element analysis (FEA) was performed to analyze contact stress of hip joint during a gait cycle of left foot.In the inverse dynamic analysis, the dynamic changes of the main hip-femoral muscle force with respect to each phase of a single gait cycle were plotted. The hip joint reaction force reached a maximum value of 2.9%BW (body weight) and appeared at the end of the terminal stance phase. Twin peaks appeared at the initial contact phase and the end of the terminal stance phase, respectively. FEA showed the temporal changes in contact stress in the acetabulum. In the visual stress cloud chart, the acetabular contact stress was mainly distributed in the dome of the acetabulum and in the anterolateral area at the top of the femoral head during a single gait cycle. The acetabular contact area was between 293.8 and 998.4 mm2, and the maximum contact area appear at the mid-stance phase or the loading response phase of gait. The maximum contact stress of the acetabulum reached 6.91 MPa for the model 1 and 6.92 MPa for the model 2 at the terminal stance phase.The "Gait-MS-FE" technology is integrated to construct a comprehensive simulation framework. Based on human gait trajectories and their CT images, individualized simulation modeling can be achieved. Subject-specific gait in combination with an inverse dynamic analysis of the MS provides pre-processing parameters for FE simulation for more accurate biomechanical analysis of hip joint.© 2022. The Author(s).

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 医学
小类 | 3 区 骨科
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 骨科
JCR分区:
出版当年[2020]版:
Q2 ORTHOPEDICS
最新[2023]版:
Q1 ORTHOPEDICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]The First Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, Guangdong, China. [2]The Lab of Orthopaedics of ChineseMedicine of Lingnan Medical Research Center, Guangzhou University of Chinese Medicine, Guangzhou 510405, Guangdong, China. [3]Department of Joint Orthopaedic, the First Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou 510405, Guangdong, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号