高级检索
当前位置: 首页 > 详情页

Reliability of shear wave elastography for the assessment of gastrocnemius fascia elasticity in healthy individual.

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Shenzhen Dapeng New District Nan’ao People’s Hospital, Branch of the First Affiliate of Shenzhen University, No.6 Renmin Road, Nanao street, Dapeng New District, Shenzhen, Guangdong Province, China [2]Clinical Medical College of Acupuncture, Moxibustion and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, China [3]The First Affiliated Hospital of Shenzhen University, Shenzhen Second People’s Hospital, No. 3002, Sungang West Road, Futian District, Shenzhen City, Guangdong Province, China.
出处:
ISSN:

摘要:
The mechanical properties of the deep fascia, particularly their stiffness, strongly affect the development of muscle pathologies (such as compartment syndrome) and the action of the muscles. However, the mechanical characteristics of the deep muscular fascia are still not clearly understood. The present study focuses on examining the reliability of ultrasonic shear wave elastography (USWE) devices in quantifying the shear modulus of the gastrocnemius fascia in healthy individuals, particularly their ability to measure the shear modulus of the deep fascia of the gastrocnemius during ankle dorsiflexion. Twenty-one healthy males (age: 21.48 ± 1.17 years) participated in the study. Using USWE, the shear moduli of the medial gastrocnemius fascia (MGF) and lateral gastrocnemius fascia (LGF) were quantified at different angles during passive lengthening. The two operators took turns measuring each subject's MGF and LGF over a 1-h period, and operator B took an additional measurement 2 h later. For the intra-operator test, the same subjects were measured again at the same time of day 5 days later. Both the intrarater [intraclass correlation coefficient (ICC) = 0.846-0.965)] and interrater (ICC = 0.877-0.961) reliability values for measuring the shear moduli of the MGF and LGF were rated as excellent; the standard error of the mean (SEM) was 3.49 kPa, and the minimal detectable change (MDC) was 9.68 kPa. Regardless of the ankle angle, the shear moduli of the LGF were significantly greater than that of the MGF (p < 0.001). Significant increases in the shear moduli of both the MGF and the LGF were observed in the neutral position compared to the relaxed position. These results indicate that USWE is a reliable technique to assess the shear modulus of the gastrocnemius fascia and detect its dynamic changes during ankle dorsiflexion. USWE can be used for biomechanical studies and intervention experiments concerning the deep fascia.© 2022. The Author(s).

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
最新[2025]版:
大类 | 3 区 综合性期刊
小类 | 3 区 综合性期刊
JCR分区:
出版当年[2020]版:
Q1 MULTIDISCIPLINARY SCIENCES
最新[2023]版:
Q1 MULTIDISCIPLINARY SCIENCES

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]Shenzhen Dapeng New District Nan’ao People’s Hospital, Branch of the First Affiliate of Shenzhen University, No.6 Renmin Road, Nanao street, Dapeng New District, Shenzhen, Guangdong Province, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号