高级检索
当前位置: 首页 > 详情页

Application value of Qisexingtai hand diagnostic method in diagnosis of coronary artery disease

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ CSCD-C ◇ 卓越:梯队期刊

机构: [1]China Acad Chinese Med Sci, Inst Hist Chinese Med & Med Literature, Beijing 100700, Peoples R China [2]China Acad Chinese Med Sci, Grad Sch, Beijing 100700, Peoples R China [3]China Acad Chinese Med Sci, Inst Basic Res Clin Med, Beijing 100700, Peoples R China [4]Guizhou Univ Tradit Chinese Med, China Chest Pain Ctr, Affiliated Hosp 2, Guizhou 550003, Peoples R China [5]China Acad Chinese Med Sci, Guanganmen Hosp, Beijing 100053, Peoples R China [6]Guangdong Prov Hosp Tradit Chinese Med, Dept Cardiovasc Dis, Guangzhou 510120, Peoples R China
出处:
ISSN:

关键词: hand diagnosis coronary artery disease diagnostic tests routine Qisexingtai

摘要:
OBJECTIVE: To evaluate the diagnostic efficacy of Qisexingtai hand diagnostic method in the diagnosis of coronary artery disease (CAD). METHODS: This was an investigator-initiated, prospective, multi-center, cross-sectional study. All the participants from three hospitals in China had been diagnosed by both Qisexingtai hand diagnostic method and coronary angiography. We compared the two diagnostic methods to calculate the sensitivity, the specificity, the omission diagnostic rate, the mistaken diagnostic rate and accuracy in order to evaluate the diagnostic efficacy of Qisexingtai hand diagnostic method for CAD. RESULTS: A total of 326 subjects were enrolled, diagnosed by both Qisexingtai hand diagnostic method and coronary angiography. As a result, there were 166 positive cases according to Qisexingtai hand diagnostic method, and 131 positive cases according to coronary angiography. Compared with the results of coronary angiography, the sensitivity of Qisexingtai hand dia-gnostic method was 80.2%, the specificity was 68.7%, the omission diagnostic rate was 19.8%, the mistaken diagnostic rate was 31.3%, and the accuracy was 73.3%. Area under the receiver operating characteristic curve was estimated as 0.735 for all, and 0.718, 0.735, 0.783 for the three sub-centers.CONCLUSION: Qisexingtai hand diagnostic method with high accuracy and sensitivity has certain application value in the diagnosis of CAD.(c) 2022 JTCM. All rights reserved.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 4 区 医学
小类 | 4 区 全科医学与补充医学
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 全科医学与补充医学
JCR分区:
出版当年[2020]版:
Q4 INTEGRATIVE & COMPLEMENTARY MEDICINE
最新[2023]版:
Q2 INTEGRATIVE & COMPLEMENTARY MEDICINE

影响因子: 最新[2023版] 最新五年平均 出版当年[2020版] 出版当年五年平均 出版前一年[2019版] 出版后一年[2021版]

第一作者:
第一作者机构: [1]China Acad Chinese Med Sci, Inst Hist Chinese Med & Med Literature, Beijing 100700, Peoples R China
通讯作者:
通讯机构: [1]China Acad Chinese Med Sci, Inst Hist Chinese Med & Med Literature, Beijing 100700, Peoples R China [*1]Institute for the History of Chinese Medicine and Medical Literature, China Academy of Chinese Medical Sciences, Beijing 100700, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号