Development of a glucose reference material in human serum for clinical assay standardization

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Laboratory Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine (Guangdong Provincial Hospital of Chinese Medicine), Guangzhou 510120, China [2]Second Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, China
出处:
ISSN:

关键词: Reference material Blood glucose Homogeneity Stability Commutability Traceability

摘要:
Blood glucose is an important monosaccharide functioning as the main source of energy for the human body. The accurate measurement of blood glucose is crucial for the screening, diagnosis, and monitoring of diabetes and diabetes-associated diseases. To assure the reliability and traceability of blood glucose measurements, we developed a reference material (RM) for use in human serum at two different concentrations, which were certified by the National Institute of Metrology (NIM) as GBW(E)091040 and GBW(E)091043.Raw serum samples were collected from residual samples after clinical testing, filtered, and repackaged under mild stirring. The homogeneity and stability of the samples were examined according to ISO Guide 35: 2017. Commutability was evaluated in compliance with CLSI EP30-A. Value assignment was carried out in six certified reference laboratories using the JCTLM-listed reference method for serum glucose. Moreover, the RMs was further applied in a trueness verification program.The developed RMs was homogeneous and commutable enough for clinical use. They were also stable for 24 h at 2-8 ℃ or 20-25 ℃ and for at least 4 years at - 70 ℃. The certified values were 5.20 ± 0.18 mmol/L and 8.18 ± 0.19 mmol/L (k = 2) for GBW(E)091040 and GBW(E)091043, respectively. The pass rates were evaluated by bias, coefficient of variation (CV), and total error (TE) for 66 clinical laboratories in the trueness verification program were 57.6%, 98.5%, and 89.4% of GBW(E)091040, and 51.5%, 98.5%, and 90.9% of GBW(E)091043, respectively.The developed RM could be used for the standardization of reference and clinical systems with satisfactory performance and traceable values, providing strong support for the accurate measurement of blood glucose.Copyright © 2023 Elsevier B.V. All rights reserved.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 3 区 医学
小类 | 2 区 分析化学 3 区 药学
最新[2025]版:
大类 | 3 区 医学
小类 | 2 区 分析化学 3 区 药学
JCR分区:
出版当年[2021]版:
Q2 CHEMISTRY, ANALYTICAL Q3 PHARMACOLOGY & PHARMACY
最新[2023]版:
Q2 CHEMISTRY, ANALYTICAL Q2 PHARMACOLOGY & PHARMACY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Laboratory Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine (Guangdong Provincial Hospital of Chinese Medicine), Guangzhou 510120, China [2]Second Clinical Medical College, Guangzhou University of Chinese Medicine, Guangzhou 510405, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号