高级检索
当前位置: 首页 > 详情页

Dosimetry study of Auto-VMAT planning and Manual-VMAT planning based on Pinnacle3 9.10 in radiotherapy for cervical cancer

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Radiotherapy, Zhongshan Hospital of Traditional Chinese Medicine, Guangdong Province, Zhongshan, China. [2]Department of Radiotherapy, The Fifth Affiliated Hospital of Guangzhou Medical University, Guangdong Province, Guangzhou, China.
出处:
ISSN:

关键词: auto-VMAT plan cervical cancer manual-VMAT plan

摘要:
The purpose of this study was to compare the dose distribution characteristics of automatic volume-modulated arc therapy (Auto-VMAT) planning and manual volume-modulated arc therapy (Manual-VMAT) planning of Philips Pinnacle3 9.10 planning system, to provide a basis for optimal radiation therapy planning for cervical cancer. Ten patients with cervical cancer in our hospital from September to December 2018 were selected, and 2 treatment plans, Auto-VMAT plan and Manual-VMAT plan, were designed using Pinnacle3 9.10 planning system, respectively, to evaluate the maximum dose Dmax, mean dose Dmean, homogeneity index of the target area according to the dose volume histogram, the conformability index, plan optimization time, monitor units (MUs), organ at risk and other indicators. The results were that the Auto-VMAT plan was superior to the Manual-VMAT plan for target area Dmean, conformability index, and homogeneity index, with statistically significant differences (P < .05) and no significant difference in maximum dose Dmax (P > .05); rectal V40, V50, and Dmean in the Auto-VMAT plan, bladder V40, V50, and Dmean, small bowel V30, V40, V50 and Dmean, and right and left femoral V50 and Dmean were all lower than the Manual-VMAT plan, and the difference was statistically significant (P < .05); the mean optimization time for the Auto-VMAT and Manual-VMAT plans was 47 minutes and 35 minutes, respectively, an increase of 34%. The average number of MUs was 519 MUs and 374 MUs, respectively, an increase of 28%. This study concluded that the Pinnacle3 9.10-based Auto-VMAT plan was clinically feasible and significantly superior to the Manual-VMAT plan in terms of improved target area uniformity and conformability and reduced organ endangerment dose while reducing the impact of human factors on the quality of plan design.Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
第一作者:
第一作者机构: [1]Department of Radiotherapy, Zhongshan Hospital of Traditional Chinese Medicine, Guangdong Province, Zhongshan, China.
通讯作者:
通讯机构: [1]Department of Radiotherapy, Zhongshan Hospital of Traditional Chinese Medicine, Guangdong Province, Zhongshan, China. [*1]Department of Radiotherapy, Zhongshan Hospital of Traditional Chinese Medicine, Guangdong Province, Zhongshan 528400, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2022 今日访问量:0 总访问量:648 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号