A biomechanical investigation of a novel intramedullary nail used to salvage failed internal fixations in intertrochanteric fractures

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]The Second Afliated Hospital of Guangzhou University of Traditional Chinese Medicine (Guangdong Provincial Hospital of Traditional Chinese Medicine), Guangzhou University of Chinese Medicine, Guangzhou 510120, China. [2]Panyu Hospital of Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou 511401, China.
出处:
ISSN:

关键词: Intertrochanteric fracture Revision surgery PFBN PFNA FEA

摘要:
The ideal approach for revision surgery following femoral head salvage treatments for an intertrochanteric fracture is still up for debate. A novel variety of proximal femoral bionic intramedullary nail (PFBN) has been created in clinical practice. We aimed to compare the biomechanical results of the novel implant to conventional intramedullary and extramedullary fixation in the treatment of intertrochanteric fracture following primary internal fixation failure.Using finite element analysis, we created a three-dimensional model of the intertrochanteric fracture's helical blade cut-out for this investigation. The PFBN 1 group, the PFBN 2 group, the PFNA group, and the DHS group were our four test groups. For each fracture group, the von Mises stress and displacements of the femur and internal fixation components were measured under 2100 N axial loads.The values for the femoral displacement in the PFBN1 group, PFBN2 group, PFNA group, and DHS group were 6.802 mm, 6.716 mm, 8.080 mm, and 8.679 mm, respectively. The internal implant displacement values were 6.201 mm, 6.138 mm, 7.396 mm, and 8.075 mm in the PFBN1 group, PFBN2 group, PFNA group, and DHS group, respectively. The maximum von Mises Stress in the femoral was 187.2 MPa, 85.18 MPa, 106.6 MPa, and 386.2 MPa in the PFBN1 groups, PFBN2 groups, PFNA groups, and DHS groups, respectively. In the PFBN1 groups, PFBN2 groups, PFNA groups, and DHS groups, the maximum von Mises Stress in internal fixation was 586.7 MPa, 559.8 MPa, 370.7 MPa, and 928.4.8 MPa, respectively.Our biomechanical research demonstrates that intramedullary fixation is more stable than extramedullary fixation when salvaging failed internal fixations in intertrochanteric fracture. Compared with PFNA and DHS, PFBN showed better biomechanical stability in the treatment of patients with revised intertrochanteric fractures. In light of this, we advocate PFBN fixation as the method of choice for intertrochanteric fracture revision. This result still has to be confirmed in more clinical research.© 2023. BioMed Central Ltd., part of Springer Nature.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 3 区 医学
小类 | 3 区 骨科
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 骨科
JCR分区:
出版当年[2021]版:
Q2 ORTHOPEDICS
最新[2023]版:
Q1 ORTHOPEDICS

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]The Second Afliated Hospital of Guangzhou University of Traditional Chinese Medicine (Guangdong Provincial Hospital of Traditional Chinese Medicine), Guangzhou University of Chinese Medicine, Guangzhou 510120, China.
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题