Breast cancer pre-clinical screening using infrared thermography and artificial intelligence: a prospective, multicentre, diagnostic accuracy cohort study

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Departments of Breast Surgery, Beijing, China [2]Tsinghua University, Beijing, China [3]Department of Thoracic Surgery, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, China [4]Department of Radiology, Xiangtan Central Hospital, China [5]Community Health Service Guidance Center, Shanxi Provincial People's Hospital, China [6]Department of Oncology, Langfang People's Hospital, Hebei, China [7]Anesthesia Operation Center, Longhui People's Hospital, Hunan, China [8]Department of General Surgery, University-Town Hospital of Chongqing Medical University, Chongqing, China [9]Department of Breast Surgery, Baoji Maternal and Child Health Hospital, Shaanxi, China [10]Department of General Surgery, ZhaLanTun Hospital of Traditional Chinese Medicine, Inner Mongolia, Xinjiang, China [11]Department of Radiology and Otolaryngology, Karamay Center Hospital, Xinjiang, China [12]Radiology, Peking Union Medical College Hospital, Qinghai, China [13]Department of Breast Surgery, Qinghai Provincial People's Hospital, Qinghai, China [14]Department of General Surgery, Shenzhen People's Hospital, Guangdong, China.
出处:
ISSN:

关键词: breast cancer infrared thermography screening artificial intelligence accuracy

摘要:
Given the limited access to breast cancer (BC) screening, the authors developed and validated a mobile phone-artificial intelligence-based infrared thermography (AI-IRT) system for BC screening.This large prospective clinical trial assessed the diagnostic performance of the AI-IRT system. The authors constructed two datasets and two models, performed internal and external validation, and compared the diagnostic accuracy of the AI models and clinicians. Dataset A included 2100 patients recruited from 19 medical centres in nine regions of China. Dataset B was used for independent external validation and included 102 patients recruited from Langfang People's Hospital.The area under the receiver operating characteristic curve of the binary model for identifying low-risk and intermediate/high-risk patients was 0.9487 (95% CI: 0.9231-0.9744) internally and 0.9120 (95% CI: 0.8460-0.9790) externally. The accuracy of the binary model was higher than that of human readers (0.8627 vs. 0.8088, respectively). In addition, the binary model was better than the multinomial model and used different diagnostic thresholds based on BC risk to achieve specific goals.The accuracy of AI-IRT was high across populations with different demographic characteristics and less reliant on manual interpretations, demonstrating that this model can improve pre-clinical screening and increase screening rates.Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 2 区 医学
小类 | 2 区 外科
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 外科
JCR分区:
出版当年[2021]版:
Q1 SURGERY
最新[2023]版:
Q1 SURGERY

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Departments of Breast Surgery, Beijing, China
共同第一作者:
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号