Deep Learning-Based Reconstruction Improves the Image Quality of Low-Dose CT Colonography

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China [2]Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China [3]Department of Radiology, Jinling Hospital, the First School of Clinical Medicine, Southern Medical University, Nanjing, Jiangsu 210002, China [4]Department of Radiology, Guangdong Second Traditional Chinese Medicine Hospital, Guangzhou, Guangdong 510095, China [5]Department of Radiology, the First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi 530021, China [6]Medical Imaging Center, the First People’s Hospital of Kashi Area, Kashi, Xinjiang 844000, China [7]Department of Radiology, the Second Hospital of Shanxi Medical University, Taiyuan, Shanxi 030001, China [8]School of Computer Science, Qufu Normal University, Rizhao, Shandong 276826, China
出处:
ISSN:

关键词: Colonography Computed Tomographic Deep learning Radiation protection

摘要:
To evaluate the image quality of low-dose CT colonography (CTC) using deep learning-based reconstruction (DLR) compared to iterative reconstruction (IR).Adults included in the study were divided into four groups according to body mass index (BMI). Routine-dose (RD: 120 kVp) CTC images were reconstructed with IR (RD-IR); low-dose (LD: 100kVp) images were reconstructed with IR (LD-IR) and DLR (LD-DLR). The subjective image quality was rated on a 5-point scale by two radiologists independently. The parameters for objective image quality included noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The Friedman test was used to compare the image quality among RD-IR, LD-IR and LD-DLR. The KruskalWallis test was used to compare the results among different BMI groups.A total of 270 volunteers (mean age: 47.94 years ± 11.57; 115 men) were included. The effective dose of low-dose CTC was decreased by approximately 83.18% (5.18mSv ± 0.86 vs. 0.86mSv ± 0.05, P < 0.001). The subjective image quality score of LD-DLR was superior to that of LD-IR (3.61 ± 0.56 vs. 2.70 ± 0.51, P < 0.001) and on par with the RD- IR's (3.61 ± 0.56 vs. 3.74 ± 0.52, P = 0.486). LD-DLR exhibited the lowest noise, and the maximum SNR and CNR compared to RD-IR and LD-IR (all P < 0.001). No statistical difference was found in the noise of LD-DLR images between different BMI groups (all P > 0.05).Compared to IR, DLR provided low-dose CTC with superior image quality at an average radiation dose of 0.86mSv, which may be promising in future colorectal cancer screening.Copyright © 2024 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
第一作者:
第一作者机构: [1]Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China [2]Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China [3]Department of Radiology, Jinling Hospital, the First School of Clinical Medicine, Southern Medical University, Nanjing, Jiangsu 210002, China
通讯作者:
通讯机构: [1]Department of Radiology, the Six Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China [2]Biomedical Innovation Center, the Sixth Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510655, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号