A comparison of invasive arterial blood pressure measurement with oscillometric non-invasive blood pressure measurement in patients with sepsis

文献详情

资源类型:
Pubmed体系:
机构: [1]Candidate of Master's Degree, The First Clinical Medical College, Guangzhou University of Chinese Medicine, Baiyun District, Guangzhou, Guangdong Province, China. [2]The First Affiliated Hospital of Guangzhou University of Chinese Medicine, 16 Jichang Road, Baiyun District, Guangzhou, Guangdong Province, China. [3]The First Affiliated Hospital of Guangzhou University of Chinese Medicine, 16 Jichang Road, Baiyun District, Guangzhou, Guangdong Province, China. dr.zuo@163.com.
出处:
ISSN:

关键词: invasive blood pressure measurement non-invasive blood pressure measurement sepsis

摘要:
This study aimed to compare non-invasive oscillometric blood pressure (NIBP) measurement with invasive arterial blood pressure (IBP) measurement in patients with sepsis.We conducted a retrospective study to evaluate the agreement between IBP and NIBP using the Medical Information Mart for Intensive Care IV (MIMIC-IV) database. Paired blood pressure measurements of mean arterial pressure (MAP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) were compared using Bland-Altman analysis and paired Student's t test. We also focus on the effect of norepinephrine (NE) on the agreement between the two methods and the association between blood pressure and mortality during intensive care unit (ICU) stay.A total of 96,673 paired blood pressure measurements from 6060 unique patients were analyzed in the study. In Bland-Altman analysis, the bias (± SD, 95% limits of agreement) was 6.21 mmHg (± 12.05 mmHg, - 17.41 to 29.83 mmHg) for MAP, 0.39 mmHg (± 19.25 mmHg, - 37.34 to 38.12 mmHg) for SBP, and 0.80 mmHg (± 12.92 mmHg, - 24.52 to 26.12 mmHg) for DBP between the two techniques. Similarly, large limits of agreement were shown in different groups of NE doses. NE doses significantly affected the agreement between IBP and NIBP. SBP between the two methods gave an inconsistent assessment of patients' risk of ICU mortality.IBP and NIBP were not interchangeable in septic patients. Clinicians should be aware that non-invasive MAP was clinically and significantly underestimated invasive MAP.© 2024. The Author(s) under exclusive licence to Japanese Society of Anesthesiologists.

语种:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 3 区 医学
小类 | 4 区 麻醉学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 麻醉学
第一作者:
第一作者机构: [1]Candidate of Master's Degree, The First Clinical Medical College, Guangzhou University of Chinese Medicine, Baiyun District, Guangzhou, Guangdong Province, China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2020 今日访问量:0 总访问量:646 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号