Three‑dimensional finite element analysis: Anatomical splint fixation for Colles fractures

文献详情

资源类型:
Pubmed体系:

收录情况: ◇ 预警期刊

机构: [1]Department of Traumatology, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China. [2]Department of Operating Room, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China.
出处:
ISSN:

关键词: Colles fracture anatomical splint finite element analysis median rotation

摘要:
With the rapid development of digital research in clinical orthopedics, the efficacy and safety of splint fixation can be better evaluated through biomechanical analysis based on a three-dimensional (3D) finite element model. It is essential to address the current gap in understanding the biomechanical implications of anatomical splint fixation for Colles fractures. By employing advanced 3D finite element analysis, the present study aimed to provide a comprehensive evaluation, offering valuable insights that can contribute to enhancing the effectiveness of anatomical splint fixation in the clinical management of Colles fractures. The 3D finite element models of the forearm and hand were constructed using Mimics 15.0 according to data from computed tomography of a patient with a Colles fracture. After the validity of the model was verified, the corresponding material properties of the models were adjusted to simulate a Colles fracture. Subsequently, the reduction functions, such as radial inclination and ulnar deviation, of the simulated fracture were completed and the mechanical changes of the tissues surrounding the fracture were calculated. Anatomical splints were then placed on the surfaces of the 3D finite element models of Colles fractures at various positions to analyze the changes in the stress cloud diagram, such as for the soft tissue and anatomical splints. In the present study, the constructed 3D finite element models were accurate and valid. The maximum stress of the anatomical splints and soft tissues was 2.346 and 0.106 MPa in pronation, 1.780 and 0.069 MPa in median rotation and 3.045 and 0.057 MPa in supination, respectively. Splint stress reached the highest level in supination and soft tissue stress achieved the highest level in pronation. The peak of splint stress occurred during supination, which contrasts to the peak of soft tissue stress observed in pronation, suggesting splint fixation median rotation can effectively avoid compression of the local soft tissue.Copyright: © Huang et al.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2023]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学:研究与实验
第一作者:
第一作者机构: [1]Department of Traumatology, The Third Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, Guangdong 510000, P.R. China.
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号