机构:[1]Department of Orthopedic Surgery, Guangzhou University of Traditional Chinese Medicine, Guangzhou City[2]Department of Orthopedic Surgery, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou,Guangdong Province, People’s Republic of China大德路总院骨科广东省中医院
Rationale: Less-Invasive Stabilization System (LISS) plate is an internal fixation commonly used for the periprosthetic distal femur fractures. Failure associated with LISS plate has been rarely reported, and the reasons for LISS plate failure are multitudinous. Various advantages have been reported, but failures continue. Patient concerns: We present 3 cases illustrating the failure of Less-Invasive Stabilization System (LISS) plating for periprosthetic distal femur fractures. The shaft screws of the LISS plate broke in 2 cases, and the plate placement was incorrect in 1 case. Early weight bearing, obesity, osteoporosis, and lateral collateral ligament injury due to incorrect plate placement constituted the etiologies of LISS plate failure. Diagnosis: Failure of Less-Invasive Stabilization System (LISS) plating for periprosthetic distal femur fractures after Total knee arthroplasty. Interventions: Three patients underwent Less-Invasive Stabilization System plates removal with replacement of the total knee arthroplasty revision surgery with rotating hinged knee prosthesis. Outcomes: After completing the total knee arthroplasty revision surgery, all patients underwent regular follow-up examinations. Case 2 could walk unaided, without pain, final union was confirmed for both case 1 and case 3. Conclusion: Less-Invasive Stabilization System (LISS) plate provides satisfactory results in periprosthetic fractures after Total knee arthroplasty (TKA). The LISS plate has many advantages, but failures continue to occur. The causes for failure were early weight bearing, obesity, osteoporosis, and lateral collateral ligament (LCL) injury due to incorrect plate placement in our series. We recommend that protection or properly delay of weight-bearing, active anti-osteoporosis treatment, and intraoperative fluoroscopy are the effective methods to avoid failure.
基金:
Natural Science Foundation of Guangdong ProvinceNational Natural Science Foundation of Guangdong Province [2018A030313643]
第一作者机构:[1]Department of Orthopedic Surgery, Guangzhou University of Traditional Chinese Medicine, Guangzhou City
通讯作者:
通讯机构:[2]Department of Orthopedic Surgery, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, Guangzhou,Guangdong Province, People’s Republic of China[*1]Department of Orthopedic Surgery, The Second Affiliated Hospital of Guangzhou University of Traditional Chinese Medicine, No. 55 East Ring Road, Guangzhou 510000, Guangdong Province, People’s Republic of China
推荐引用方式(GB/T 7714):
Tian Zhen-Jiang,Liu Yan-Jie,Chen Bo-Jian,et al.Failure of Less-Invasive Stabilization System (LISS) plating for periprosthetic distal femur fractures Three case reports[J].MEDICINE.2020,99(8):doi:10.1097/MD.0000000000019195.
APA:
Tian Zhen-Jiang,Liu Yan-Jie,Chen Bo-Jian,Wang Jun,Niu Cai-Li...&Huang Yong-Ming.(2020).Failure of Less-Invasive Stabilization System (LISS) plating for periprosthetic distal femur fractures Three case reports.MEDICINE,99,(8)
MLA:
Tian Zhen-Jiang,et al."Failure of Less-Invasive Stabilization System (LISS) plating for periprosthetic distal femur fractures Three case reports".MEDICINE 99..8(2020)