Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion.
机构:[1]Department of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, P.R. China[2]Department of Orthopedics, Hunan Provincial People’s Hospital, Changsha, Hunan, P.R. China[3]Department of Orthopedics, The Third Affiliated Hospital of Southern Medical University, Guangzhou, Guangdong, P.R. China[4]Department of Traumatology, The Second Affiliated Hospital of Inner Mongolia Medical University, Hohhot, Inner Mongolia, P.R. China[5]Department of Clinical Laboratory Medicine, Hospital of Traditional Chinese Medicine of Zhongshan, Zhongshan, Guangdong, P.R. China
BACKGROUND The aim of this study was to provide valid data for a plate-screw fixation model for fractured posterior-anterior columns of the acetabulum. MATERIAL AND METHODS Nineteen cadaveric bony hemi-pelvis specimens were obtained and 50 healthy adults were enrolled. The modified Stoppa approach and computed tomography (CT) imaging were used to collect the measured parameter data of the module. RESULTS The measured parameter data were as follows: OP, 0.96±0.32 cm in females and 0.92±0.16 cm in males (P>0.05); PI, 0.98±0.28 cm in females, and 0.75±0.23 cm in males (P>0.05); Ðϴ, 59.68°±6.28° in females and 56.75°±3.22° in males (P>0.05); and Ðφ, 41.27°±2.76° in females and 34.31°±2.78° in males (P<0.05). The corresponding CT image data were as follows: PI, 1.08±0.22 cm in females and 0.85±0.27 cm in males (P>0.05); OP, 1.06±0.29 cm in females and 1.12±0.24 cm in males (P>0.05); Ðϴ, 55.33°±4.00° in females and 55. 50°±3.43° in males (P>0.05); and Ðφ was 39.21°±2.45°in females and 35.58°±2.31°in males (P<0.05). No significant difference with respect to sex and side existed between specimens and healthy adults (P>0.05). CONCLUSIONS The measured parameter data obtained in healthy adults and cadaveric specimens provided an anatomic basis for the designation of the guide module, and thus confirmed the accuracy and safety of screw placement in fractured columns of the acetabulum.
基金:
Natural Science Foundation of Guangdong Province (no. 10151051501000085)
语种:
外文
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类|4 区医学
小类|4 区医学:研究与实验
最新[2025]版:
大类|4 区医学
小类|4 区医学:研究与实验
第一作者:
第一作者机构:[1]Department of Orthopedics and Traumatology, Nanfang Hospital, Southern Medical University, Guangzhou, Guangdong, P.R. China[2]Department of Orthopedics, Hunan Provincial People’s Hospital, Changsha, Hunan, P.R. China
通讯作者:
推荐引用方式(GB/T 7714):
Xu Yongqiang,Lin Chuangxin,Zhang Lifeng,et al.Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion.[J].Medical science monitor : international medical journal of experimental and clinical research.2016,22:3106-12.doi:10.12659/msm.896313.
APA:
Xu Yongqiang,Lin Chuangxin,Zhang Lifeng,Lin Miaoxiong,Lai Jianqiang...&Wang Gang.(2016).Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion..Medical science monitor : international medical journal of experimental and clinical research,22,
MLA:
Xu Yongqiang,et al."Anterograde Fixation Module for Posterior Acetabular Column Fracture: Computer-Assisted Determination of Optimal Entry Point, Angle, and Length for Screw Insertion.".Medical science monitor : international medical journal of experimental and clinical research 22.(2016):3106-12