高级检索
当前位置: 首页 > 详情页

Appraising the Accuracy of Ischaemia-Modified Albumin in Diagnosing Stroke: A Systematic Review and Meta-Analysis

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [a]The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China [b]Emergency Department, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, China
出处:
ISSN:

关键词: Diagnosis Stroke Ischaemia

摘要:
Introduction: Ischaemia-modified albumin (IMA) is a new, sensitive marker of ischaemic diseases that has been approved for diagnosing myocardial ischaemia. However, the accuracy of IMA in the diagnosis of stroke remains to be clarified. The study's purpose is to assess the potential role of IMA as a diagnostic indicator in stroke. Methods: We carried out a systematic search in Medline, the Cochrane Library, Embase, Scopus, Science Direct, ISI Web of Knowledge, and the reference lists of relevant articles from the databases' inception to September 1, 2019. Studies that appraised the diagnostic accuracy of IMA for acute stroke patients were included in our study. Two reviewers extracted data independently and assessed the quality of the retrieved studies, and disagreements were resolved through discussions with a third reviewer. Sensitivities and specificities were pooled by using bivariate diagnostic meta-analysis. We calculated I-2 to test the heterogeneity and used meta-regression to identify potential sources of heterogeneity. This systematic review and meta-analysis is registered in international prospective register of systematic reviews (number CRD42020149174). Results: Six studies with 605 patients were eligible for inclusion. Our meta-analysis produced the following outcomes: the mean sensitivity of IMA in diagnosing acute stroke was 0.80 (95% confidence interval [CI], 0.69-0.88) and the specificity was 0.80 (95% CI, 0.71-0.87). The area under the receiver operating characteristic curve was 0.86 (95% CI, 0.83-0.89), and the pooled diagnostic odds ratio was 16 (95% CI, 8-33). There was obvious heterogeneity between studies (I-2 = 78%, 95% CI, 53-100). Sensitivity analysis and meta-regression could account for the heterogeneity. Conclusion: IMA is a helpful marker for consideration in the early diagnosis of stroke.

基金:

基金编号: No. 2017B030314176

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 3 区 医学
小类 | 3 区 临床神经病学 3 区 外周血管病
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 临床神经病学 4 区 外周血管病
JCR分区:
出版当年[2019]版:
Q2 CLINICAL NEUROLOGY Q2 PERIPHERAL VASCULAR DISEASE
最新[2023]版:
Q3 CLINICAL NEUROLOGY Q3 PERIPHERAL VASCULAR DISEASE

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [a]The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号