高级检索
当前位置: 首页 > 详情页

Significance of different offending vessels and development of a potential screening tool for trigeminal neuralgia.

文献详情

资源类型:
Pubmed体系:
机构: [1]Department of Neurosurgery, Guangdong Second Provincial General Hospital, 466 Xingang Middle Road, Guangzhou, China [2]Department of Surgery, Yuwotou Hospital of Nansha District, Guangzhou, China [3]Department of Neurosurgery, People’s Hospital of Ningxiang City, Hunan University of Traditional Medicine, Ningxiang, China [4]The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China
出处:
ISSN:

关键词: Trigeminal neuralgia Radiologic factors Screening tool

摘要:
This study was performed amongst trigeminal neuralgia (TN) patients with neurovascular contact (NVC) to 1) investigate the association of the demographic and radiologic factors/variables with TN occurrence, and 2) develop a screening tool for TN/TN-affected nerves based on the factors/variables associated with it.Eighty-five TN patients were recruited, and 121 trigeminal nerves with NVC were derived from them. Based on MRI sequences, including balanced turbo field echo and enhanced T1 high-resolution isotropic volume excitation, radiologic factors/variables for each nerve, from the offending vessel to the presence of nerve displacement, were identified by a neuroradiologist and a neurosurgeon. Demographic and clinical data were obtained from clinical notes. Logistic regression was performed to assess the association of the factors/variables with TN occurrence (i.e., affected vs. unaffected nerves).Three factors/variables were significantly (p < 0.05) associated with TN occurrence amongst patients with NVC: nerve laterality, vertebral artery (VA) involvement, and the presence of nerve displacement. The nerves with VA involvement, those on the right side, and those with nerve displacement exhibited a significantly higher likelihood/odd of being affected by TN, compared to those without VA involvement, those on the left side, and those without nerve displacement, respectively. Based on these factors/variables, a screening tool/nomogram with acceptable accuracy was established (C-statistic/AUC = 0.80).This study revealed an association of the three radiologic factors/variables with TN occurrence. A screening tool for TN/TN-affected nerves was established based on them. The findings may lay a foundation for an improvement of the diagnosis and clinical management of TN.• VA involvement and nerve displacement could be identified using MRI, and are significantly associated with TN occurrence. • A potential objective screening tool/nomogram for TN/TN-affected nerves could be established based on the three radiologic factors/variables: VA involvement, the presence of nerve displacement, and nerve laterality. • The screening accuracy of the tool/nomogram is acceptable as the C-statistic is 0.80.© 2022. The Author(s), under exclusive licence to European Society of Radiology.

基金:
语种:
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类 | 2 区 医学
小类 | 2 区 核医学
最新[2025]版:
大类 | 2 区 医学
小类 | 2 区 核医学
第一作者:
第一作者机构: [1]Department of Neurosurgery, Guangdong Second Provincial General Hospital, 466 Xingang Middle Road, Guangzhou, China
共同第一作者:
通讯作者:
通讯机构: [1]Department of Neurosurgery, Guangdong Second Provincial General Hospital, 466 Xingang Middle Road, Guangzhou, China [4]The Second School of Clinical Medicine, Southern Medical University, Guangzhou, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号