高级检索
当前位置: 首页 > 详情页

Intravascular ultrasonography assisted carotid artery stenting for treatment of carotid stenosis: Two case reports

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE ◇ 预警期刊

机构: [1]Department of Neurology, The First Affiliated Hospital of Shenzhen University, Shenzhen 518000, Guangdong Province, China. [2]Faculty of Chinese Medicine, Macau University of Science and Technology, Macau 999078, China. [3]Graduate School, Guangzhou Medical University, Guangzhou 511495, Guangdong Province, China. [4]School of Medicine, Shenzhen University, Shenzhen 518000, Guangdong Province, China. [5]Medical Department, Baise People's Hospital, Baise 533000, Guangxi Zhuang Autonomous Region, China. [6]Hunan Provincial Key Laboratory of the Research and Development of Novel Pharmaceutical Preparations, Changsha Medical University, Changsha 410219, Hunan Province, China. [7]Clinical College of the Shenzhen Second People's Hospital, Anhui Medical University, Shenzhen 518000, Guangdong Province, China
出处:
ISSN:

关键词: Intravascular ultrasonography Carotid artery stenting Carotid stenosis Arteriosclerotic stenosis Carotid artery dissection Case report

摘要:
Digital subtraction angiography (DSA), the gold standard of cerebrovascular disease diagnosis, is limited in its diagnostic ability to evaluate arterial diameter. Intravascular ultrasonography (IVUS) has advantages in assessing stenosis and plaque nature and improves the evaluation and effectiveness of carotid artery stenting (CAS).Case 1: A 65-year-old man presented with a five-year history of bilateral lower limb weakness due to stroke. Physical examination showed decreased strength (5-/5) in both lower limbs. Carotid artery ultrasound, magnetic resonance angiography, and computed tomography angiography (CTA) showed a right proximal internal carotid artery (ICA) stenosis (70%-99%), acute cerebral infarction, and severe right ICA stenosis, respectively. We performed IVUS-assisted CAS to measure the stenosis and detected a low-risk plaque at the site of stenosis prior to stent implantation. Post-stent balloon dilatation was performed and postoperative IVUS demonstrated successful expansion and adherence. CTA six months postoperatively showed no significant increase in in-stent stenosis. Case 2: A 36-year-old man was admitted with a right common carotid artery (CCA) dissection detected by ultrasound. Physical examination showed no positive neurological signs. Carotid ultrasound and CTA showed lumen dilation in the proximal CCA with an intima-like structure and bulging in the proximal segment of the right CCA with strip-like low-density shadow (dissection or carotid web). IVUS-assisted DSA confirmed right CCA dissection. CAS was performed and intraoperative IVUS suggested a large residual false lumen. Post-stent balloon dilatation was performed reducing the false lumen. DSA three months postoperatively indicated good stent expansion with mild stenosis.IVUS aids decision-making during CAS by accurately assessing carotid artery wall lesions and plaque nature preoperatively, dissection and stenosis morphology intraoperatively, and visualizing and confirming CAS postoperatively.©The Author(s) 2023. Published by Baishideng Publishing Group Inc. All rights reserved.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2022]版:
大类 | 4 区 医学
小类 | 4 区 医学:内科
最新[2025]版:
JCR分区:
出版当年[2021]版:
Q4 MEDICINE, GENERAL & INTERNAL
最新[2023]版:
Q3 MEDICINE, GENERAL & INTERNAL

影响因子: 最新[2023版] 最新五年平均 出版当年[2021版] 出版当年五年平均 出版前一年[2020版] 出版后一年[2022版]

第一作者:
第一作者机构: [1]Department of Neurology, The First Affiliated Hospital of Shenzhen University, Shenzhen 518000, Guangdong Province, China.
通讯作者:
通讯机构: [7]Clinical College of the Shenzhen Second People's Hospital, Anhui Medical University, Shenzhen 518000, Guangdong Province, China [*1]Clinical Collegeof the Shenzhen Second People’s Hospital, Anhui Medical University, No. 3002 Sungang WestRoad, Shenzhen 518000, Guangdong Province, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号