Matrix Effects in Proficiency Testing Materials Influence the Accurate Measurement of Gamma-Glutamyltransferase Activity

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Guangzhou Univ Chinese Med, Affiliated Hosp 2, Dept Lab Med, Guangzhou 510095, Guangdong, Peoples R China [2]Guangzhou Chest Hosp, Dept Lab Med, Guangzhou, Guangdong, Peoples R China
出处:
ISSN:

关键词: accuracy gamma-glutamyltransferase reference measurement procedure commutability trueness

摘要:
Background: A consensus on an accurate method to measure gamma-glutamyltransferase (GGT) activity for clinical purposes has not been achieved among practicing clinical laboratories. To improve analytical trueness, we evaluated the influences of matrix effects in proficiency testing (PT) materials on the measurement of GGT activity in human serum samples. Methods: Five fresh frozen human samples (FFS1-5) and five lyophilized proficiency testing materials (Lyo1-5) were distributed to 23 participating clinical laboratories for the measurement of GGT activity. Target GGT activity values for the samples were obtained by using previously approved reference methods. The results obtained by the Beckman Coulter Unicel DxC 800 Synchron analyzer were compared to the target values assigned by two reference laboratories, and the commutability of the lyophilized materials was evaluated according to Clinical and Laboratory Standards Institute (CLSI) guideline EP14-A2. Results: The relative bias between the results obtained by the Beckman Coulter analyzer and the reference target values ranged from -27.2% to -18.0% for FFS1-5 and from 9.1% to 2.5% for Lyo1-5. Non-commutability of all lyophilized samples falling outside of the 95% prediction interval was observed. Conclusions: The results obtained for the lyophilized PT materials were deemed acceptable within the total allowable errors, suggesting that matrix effects may impart a false sense of confidence that clinical analytical systems are performing very well. A primary reference measurement procedure on fresh frozen serum provides a valuable method for evaluating the trueness of results measured by PT.

基金:
语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2015]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
JCR分区:
出版当年[2014]版:
Q3 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q4 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2014版] 出版当年五年平均 出版前一年[2013版] 出版后一年[2015版]

第一作者:
第一作者机构: [2]Guangzhou Chest Hosp, Dept Lab Med, Guangzhou, Guangdong, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号