Application of New Reference Procedure for ALP Measurement in the Clinical Laboratory

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of Laboratory Science, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, China [2]Junhua Zhuang, Xianzhang Huang Department of L aboratory Science The Second Affiliated Hospital of Guangzhou University of Chinese Medicine Guangdong, Guangzhou 510120, China
出处:
ISSN:

关键词: alkaline phosphatase (ALP) reference measurement procedure (RMP) external quality assessment (EQA) method comparison standardization

摘要:
Background: Alkaline phosphatase (ALP) is routinely analyzed in clinical laboratories for the comprehensive assessment of hepatic and osteal diseases. The official reference measurement procedure (RMP) of ALP was released by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) in 2011. However, most of the commercial kits still trace back to the old version (1983). There was a difference between the trace measurement procedure and the RMP. Therefore, the discrepancy among clinical systems and application of the new RMP for ALP in clinical laboratories was studied. Methods: According to the recommendation of the IFCC, the RMP for ALP (2011) was reproduced. The reference measurement system (RMS) for serum ALP and 19 clinical systems were included in the external quality assessment (EQA). The relative bias was calculated between the clinical systems' results and RMS, as well as each clinical system and the average value of all clinical systems. The qualified rates (passing score in percentage) for the 19 clinical systems were compared by using two different standards. In the comparison experiment, two clinical systems were evaluated before and after calibration by RMP. The clinical acceptability at the medical decision point was evaluated. Results: The performance of the reproduced RMP for ALP was: total imprecision was 0.33% and 0.42% at 336.9 U/L and 138.74 U/L, respectively. The accuracy was in the acceptable range. Excellent linearity was obtained for linear regression (R = 0.9998). In the EQA experiment, the relative bias of clinical systems and RMP ranged from -26.36% to 19.49%, and the majority of them had a negative value. Relative bias of clinical systems and the average value of 19 clinical systems ranged from -24.28% to 33.48%. The qualified rate for clinical systems was 53% - 89% evaluated by Standard 1 and was 95% - 100% evaluated by Standard 2. In the comparison experiment, the relative bias for the two clinical systems decreased and both of the clinical systems showed less relative bias at the medical decision points after calibration by RMP. Conclusions: There was a much higher discrepancy among clinical systems for the testing of serum ALP. Traceability and standardization would likely be improved for clinical systems by the application of RMP for ALP (2011) in clinical laboratories.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
JCR分区:
出版当年[2013]版:
Q3 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q4 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Department of Laboratory Science, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou 510120, China
通讯作者:
通讯机构: [2]Junhua Zhuang, Xianzhang Huang Department of L aboratory Science The Second Affiliated Hospital of Guangzhou University of Chinese Medicine Guangdong, Guangzhou 510120, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2022 今日访问量:0 总访问量:648 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号