高级检索
当前位置: 首页 > 详情页

Reference Intervals of Serum Sodium, Potassium, and Chlorine in Chinese Han Population and Comparison of Two ISE Methods

文献详情

资源类型:
WOS体系:
Pubmed体系:

收录情况: ◇ SCIE

机构: [1]Department of Laboratory Medicine, Peking University Third Hospital, Beijing, China [2]National Center for Clinical Laboratories, Beijing Hospital, Beijing, China [3]Department of Laboratory Science, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangdong, China [4]Department of Laboratory Medicine, West China Hospital, Sichuan University, Sichuan, China [5]Department of Clinical Laboratory Medicine, Xijing Hospital, The Fourth Military Medical University, Xi’an, Shaanxi, China [6]Department of Laboratory Medicine, the First Affiliated Hospital of China Medical University, Shenyang, China [7]Department of Clinical Laboratory Medicine, Zhongshan Hospital of Fudan University, Shanghai, China
出处:
ISSN:

关键词: reference intervals potassium sodium chlorine Chinese population method comparison

摘要:
BackgroundCurrently there are no reference intervals (RIs) of sodium (Na), potassium (K), and chlorine (Cl) on Chinese population. Two kinds of ion-selective electrode (ISE) methods were commonly used to determine K, Na, and Cl levels in China, the difference between these two methods needs to be evaluated. MethodsA total of 4,524 healthy participants (1,916 males and 2,608 females) between 20-79 years old from six cities in China were selected by strict criteria. Serum K, Na, and CL were tested on Roche Modular analyzers in six assigned laboratories. According to EP-9A2, using Roche Modular analyzer (indirect ISE) as comparative method, Olympus AU 5400 analyzer (indirect ISE) and Johnson&Johnson Fusion 5.1 analyzer (direct ISE) were evaluated. ResultsIn Chinese population, the RIs for K, Na, and CL are 3.6-5.2, 136-146, and 99-110 mmol/l, respectively. Compared to the Roche indirect ISE method, Johnson direct ISE method showed a positive bias; and Olympus indirect ISE method just showed a very slight bias. ConclusionThe RIs of K, Na, and Cl of Han Chinese healthy adult population were found to be smaller than those provided by the manufacturer. By a criteria of biological variations for CV, the differences of Na and K between Roche analyzer and Johnson analyzer were not acceptable for clinical application, while the differences of Na, K, and Cl between Roche and Olympus analyzers were acceptable for clinical application.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2014]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
最新[2025]版:
大类 | 4 区 医学
小类 | 3 区 医学实验技术
JCR分区:
出版当年[2013]版:
Q3 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q2 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2013版] 出版当年五年平均 出版前一年[2012版] 出版后一年[2014版]

第一作者:
第一作者机构: [1]Department of Laboratory Medicine, Peking University Third Hospital, Beijing, China
共同第一作者:
通讯作者:
通讯机构: [6]Department of Laboratory Medicine, the First Affiliated Hospital of China Medical University, Shenyang, China [*1]Department of Laboratory Medicine, the First AffiliatedHospital of China Medical University,No. 155 Nanjing North Street, Heping District, Shenyang 110001, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号