Evaluation of the Elecsys Syphilis Assay as a Laboratory Screening Test for Syphilis

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Guangzhou Univ Chinese Med, Affiliated Hosp 2, Guangdong Prov Hosp Chinese Med, Dept Clin Lab, Guangzhou, Guangdong, Peoples R China [2]Southern Med Univ, Dept Clin Lab, Guangzhou, Guangdong, Peoples R China
出处:
ISSN:

关键词: syphilis sensitivity specificity immunoblot assay performance evaluation method comparison

摘要:
Background: The sexually transmitted infection (STI) syphilis remains a public health problem globally. The serological detection of specific antibodies to Treponema pallidum is particularly important in the diagnosis of syphilis. The purpose of this study was to evaluate the newly developed Elecsys Syphilis assay and compare it with the local market well-established ARCHITECT Syphilis TP assay. Methods: A total of 1,097 clinical serum samples were obtained from routine diagnostic requests. All the serum or plasma samples were tested in parallel by Elecsys Syphilis assay and ARCHITECT Syphilis TP assay. Sensitivity, specificity, and agreement assay were verified. The inconsistent samples confirmed with a recombinant immunoblot assay as gold standard test. Results: The diagnostic performances of the two assays were very similar: both Elecsys Syphilis and ARCHITECT Syphilis TP assay performed with a sensitivity of 100% (95% CI, 85.7 to 100%) and 100% (95% CI, 85.7 to 100%), whereas the specificity was 99.90% (95% CI, 99.5 to 99.90%) and 99.49% (95% CI, 99.0 to 99.6%), respectively. The consistency in positive results between Elecsys and ARCHITECT Syphilis TP assay was 79.3%. The consistency in negative results between Elecsys and ARCHITECT Syphilis TP assay was 99.7%. The overall consistency between Elecsys and ARCHITECT Syphilis TP assay was 99.1%. Conclusions: The Elecsys Syphilis assay can demonstrate excellent diagnostic sensitivity and specificity and correlate well with ARCHITECT Syphilis TP assay. It is a reliable and appropriate assay for routine use in a diagnostic laboratory.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2017]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
JCR分区:
出版当年[2016]版:
Q4 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q4 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2016版] 出版当年五年平均 出版前一年[2015版] 出版后一年[2017版]

第一作者:
第一作者机构: [1]Guangzhou Univ Chinese Med, Affiliated Hosp 2, Guangdong Prov Hosp Chinese Med, Dept Clin Lab, Guangzhou, Guangdong, Peoples R China
通讯机构: [1]Guangzhou Univ Chinese Med, Affiliated Hosp 2, Guangdong Prov Hosp Chinese Med, Dept Clin Lab, Guangzhou, Guangdong, Peoples R China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号