Evaluation of AutoLumo A2000 chemiluminescent immunoassay for detection of respiratory syncytial virus and adenovirus IgM antibodies

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [a]Department of Clinical Laboratory, Guangdong Provincial Hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China [b]Guangdong Women's and Children's Hospital, Guangzhou, China
出处:
ISSN:

关键词: Adenovirus AutoLumo evaluation Respiratory syncytial virus

摘要:
Background: Respiratory syncytial virus and adenovirus are seasonal diseases that cause an enormous burden on health systems. Previously, our lab uses DHI D3-Ultra DFA for detecting antigen of respiratory syncytial virus (RSV) and adenovirus (ADV). This article will evaluate the performance of AutoLumo RSV-IgM and ADV-IgM assays compared to D3-Ultra DFA method. Methods: We used quality control specimens to evaluate precision, cross-reactivity specimen to evaluate the specificity, exogenous interferent: Hb (1,000 mg/dL); total bilirubin (50 mg/dL), ANA titer (1:10,000), RF (500 IU/mL) to evaluate interference, and paired, nasopharyngeal swab and sera specimens to evaluate clinical sensitivity and specificity. Results: AutoLumo RSV-IgM and ADV-IgM assay show good precision and no cross-reactivity with other pathogen-specific IgM antibodies; no hook effect; exogenous interferent substance: Hb < 1,000 mg/dL; total bilirubin < 50 mg/dL, ANA titer < 1:10,000, and RF < 500 IU/mL showed no interference to RSV-IgM and ADV-IgM antibodies. The paired comparison test showed that RSV-IgM and ADV-IgM appear partly on the fifth day of the disease and peaked on days six to fourteen. Conclusions: AutoLumo RSV-IgM and ADV-IgM have good performance, but their sensitivities await further improvements. © 2021 Verlag Klinisches Labor GmbH. All rights reserved.

语种:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2020]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
最新[2025]版:
大类 | 4 区 医学
小类 | 4 区 医学实验技术
JCR分区:
出版当年[2019]版:
Q4 MEDICAL LABORATORY TECHNOLOGY
最新[2023]版:
Q4 MEDICAL LABORATORY TECHNOLOGY

影响因子: 最新[2023版] 最新五年平均 出版当年[2019版] 出版当年五年平均 出版前一年[2018版] 出版后一年[2020版]

第一作者:
第一作者机构: [a]Department of Clinical Laboratory, Guangdong Provincial Hospital of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China
通讯作者:
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号