机构:[1]Rehabilitation Therapy Center, Henan Province Orthopedic Hospital, Luoyang, Henan, China[2]Clinical College of Acupuncture, Moxibustion, and Rehabilitation, Guangzhou University of Chinese Medicine, Guangzhou, Guangdong, China
BACKGROUND The aims of this study were to (1) calculate the correlation between different tensile force levels and corresponding muscle stiffness both in vitro and in vivo; (2) determine whether muscle stiffness assessed using a MyotonPRO myotonometer can be used to accurately estimate muscle activity level; and (3) evaluate the inter-operator reliability of MyotonPRO-based measurement in assessing biceps brachii muscle (BBM) stiffness. MATERIAL AND METHODS In Experiment I, muscle stiffness, as measured using the MyotonPRO, was obtained at 0 N, 2 N, 4 N, 6 N, 8 N, and 10 N of applied force on 6 fresh medial gastrocnemius muscle specimens. In Experiment II, 11 healthy subjects were recruited. BBM stiffness, assessed by the same device, was obtained at different tensile force levels, from 0 to 50% of maximal voluntary contraction (MVC). For the reliability test, the score for each subject was quantified by 2 operators (I and II), thrice, at 30-minute intervals on the same day. RESULTS A strong correlation was found between the different tensile force levels, which corresponded to muscle stiffness in vitro (r=0.71-0.95, all P<0.05). In vivo, muscle stiffness increased linearly with an increase of the tensile force levels from 0 to 50% of MVC (r=0.99, P=0.00) and there was a significant difference in BBM stiffness among the incremental isometric tasks (F [1.76, 17.60]=91.52, P=0.00). The inter-operator reliability for the measurement of BBM stiffness was good (ICC=0.86). CONCLUSIONS Our findings indicate that muscle stiffness measured using the MyotonPRO is strongly related to muscle activity level and that the MyotonPRO is a feasible tool for quantifying BBM stiffness as well as for quantifying changes in MVC levels.
语种:
外文
PubmedID:
中科院(CAS)分区:
出版当年[2021]版:
大类|4 区医学
小类|4 区医学:研究与实验
最新[2025]版:
大类|4 区医学
小类|4 区医学:研究与实验
第一作者:
第一作者机构:[1]Rehabilitation Therapy Center, Henan Province Orthopedic Hospital, Luoyang, Henan, China
通讯作者:
推荐引用方式(GB/T 7714):
Li Ya-Peng,Liu Chun-Long,Zhang Zhi-Jie.Feasibility of Using a Portable MyotonPRO Device to Quantify the Elastic Properties of Skeletal Muscle.[J].Medical science monitor : international medical journal of experimental and clinical research.2022,28:e934121.doi:10.12659/MSM.934121.
APA:
Li Ya-Peng,Liu Chun-Long&Zhang Zhi-Jie.(2022).Feasibility of Using a Portable MyotonPRO Device to Quantify the Elastic Properties of Skeletal Muscle..Medical science monitor : international medical journal of experimental and clinical research,28,
MLA:
Li Ya-Peng,et al."Feasibility of Using a Portable MyotonPRO Device to Quantify the Elastic Properties of Skeletal Muscle.".Medical science monitor : international medical journal of experimental and clinical research 28.(2022):e934121