Quantitative radiomic model for predicting malignancy of small solid pulmonary nodules detected by low-dose CT screening

文献详情

资源类型:
WOS体系:

收录情况: ◇ SCIE

机构: [1]Department of Radiology, The 5th Affiliated Hospital of Sun Yat-sen University, Zhuhai 519000, China [2]Department of Radiology, The Second Affiliated Hosptial of Guangzhou University of Traditional Chinese Medicine, Guangzhou 510120, China [3]GE Healthcare, Guangzhou 510000, China
出处:
ISSN:

关键词: Radiomics CT solid pulmonary nodules prediction

摘要:
Background: It is a permanent challenge to differentiate small solid lung nodules. Massive data, extracted from medical image through radiomics analysis, may help early diagnosis of lung cancer. The aim of this study was to assess the usefulness of a quantitative radiomic model developed from baseline low-dose computed tomography (LDCT) screening for the purpose of predicting malignancy in small solid pulmonary nodules (SSPNs). Methods: This retrospective study included malignant and benign SSPNs (6 to 15 mm) detected in baseline low-dose CT screening. The malignancy was confirmed pathologically, and benignity was confirmed by long term follow-up or pathological diagnosis. The non-contrast CT images were reconstructed with a lung kernel of a slice thickness of 1 mm and were processed to extract 385 quantitative radiomic features using Analysis-Kinetic software. A predictive model was established with the training set of 156 benign and 40 malignant nodules, and was tested with the validation set of 77 benign and 21 malignant nodules through the analysis of R square. The performance of the radiomic model in predicting malignancy was compared with that of the ACR Lung Imaging Reporting and Data System (ACR lung-RADS). Results: In 294 cases of SSPNs, 61 lung cancers and 24 benign nodules were confirmed pathologically and the remaining 209 nodules were stable with long-term follow-up (4.1 +/- 0.9 years). Eleven non-redundant features, including 8 high-order texture features, were extracted from the training data set. The sensitivity and specificity of the prediction model in malignancy differentiation were 81.0% and 92.2% respectively. The accuracy was superior to ACR-lung RADS (89.8% vs. 76.5%). Conclusions: A radiomic model based on baseline low-dose CT screening for lung cancer can improve the accuracy in predicting malignancy of SSPNs.

基金:
语种:
被引次数:
WOS:
PubmedID:
中科院(CAS)分区:
出版当年[2018]版:
大类 | 3 区 医学
小类 | 3 区 核医学
最新[2025]版:
大类 | 3 区 医学
小类 | 3 区 核医学
JCR分区:
出版当年[2017]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
最新[2023]版:
Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING

影响因子: 最新[2023版] 最新五年平均 出版当年[2017版] 出版当年五年平均 出版前一年[2016版] 出版后一年[2018版]

第一作者:
第一作者机构: [1]Department of Radiology, The 5th Affiliated Hospital of Sun Yat-sen University, Zhuhai 519000, China [2]Department of Radiology, The Second Affiliated Hosptial of Guangzhou University of Traditional Chinese Medicine, Guangzhou 510120, China
通讯作者:
通讯机构: [1]Department of Radiology, The 5th Affiliated Hospital of Sun Yat-sen University, Zhuhai 519000, China [*1]No. 52 of Meihua East Road, Xiangzhou District, Zhuhai 519000, China
推荐引用方式(GB/T 7714):
APA:
MLA:

资源点击量:2018 今日访问量:0 总访问量:645 更新日期:2024-07-01 建议使用谷歌、火狐浏览器 常见问题

版权所有©2020 广东省中医院 技术支持:重庆聚合科技有限公司 地址:广州市越秀区大德路111号